Cabac C2010 Leakage Clamp Meter to 600A
Cabac C2010 Leakage Clamp Meter to 600A
The Cabac Leakage Clamp Meter to 600A is a professional, high-precision electrical diagnostic instrument engineered for specialized AC and leakage current detection across earth conductors and commercial systems. Capable of resolving highly sensitive measurements down to the low mA range, this feature-packed clamp meter combines advanced troubleshooting utilities like a low pass filter for clean voltage tracking and a Type K thermocouple for temperature verification. Enclosed in a robust chassis designed for one-handed operational efficiency, it meets strict international compliance and safety benchmarks, making it an indispensable tool for uncovering hazardous current bleeding and conducting thorough electrical audits safely.
Vendor: Cabac
Available
KEY FEATURES
- Highly accurate current clamping capable of measuring subtle leakage currents down to the low mA range.
- Perfectly engineered for detecting safety-critical leakage current paths in earth conductors.
- Integrated Low Pass Filter (LPF) strips signal noise to ensure precise voltage measurement loops.
- Features a high-contrast 3 1/2 digit, 3999-count LCD screen equipped with a bright backlight.
- Dual layout range selection gives operators complete freedom over auto or manual range controls.
- Relative measurement and max recording modes capture precise baseline deltas and load extremes.
- Strict compliance engineering meets IEC61010-1 CATIII 600V safety and C-tick standards.
- Includes dedicated continuity testing with an audible buzzer alongside a stable diode check function.
The Cabac Leakage Clamp Meter to 600A delivers a highly effective and robust electrical verification framework for auditing commercial plant systems, tracking down breakdown insulation faults, and validating earth grounding networks. Standard high-capacity industrial clamp meters often lack the high-purity processing and shielding required to resolve micro-level current leakage, leading to overlooked safety hazards or incorrect system logging; by embedding high-sensitivity low mA tracking elements directly within a secure CATIII infrastructure, this instrument ensures immediate, error-free diagnostic tracking. Field technicians can manage continuous testing loops confidently, taking control of noisy variable frequency lines via the integrated low pass filter without introducing manual reading errors.
ADDITIONAL FEATURES
- Type K thermocouple interface provides responsive contact thermal profiling capabilities on site.
- Extended duty cycle testing span covers from 0.1% to 99.9% for detailed pulse width analysis.
- On-screen data hold function freezes active measurements instantly for comfortable reading during tricky positioning tasks.
- Efficient circuit infrastructure draws stable power from three standard AAA battery cells.
- Supplied soft protective carrying bag keeps your measurement leads and technical accessories secure during everyday transit.
APPLICATIONS
- Perfectly optimized for high-accuracy AC current clamping, earth conductor leakage current detection, low mA microcurrent profiling, low pass filter voltage diagnostics, Type K contact temperature monitoring, circuit continuity validation, and safety-compliant facility engineering.
PRODUCT PACKAGE INCLUDES
- 1 x Cabac Leakage Clamp Meter to 600A (SKU: C2010)
- 1 x Premium Electrical Test Leads Set
- 1 x Point-Contact Type K Temperature Thermocouple
- 3 x Standard AAA Operational Batteries
- 1 x Soft Protective Fabric Carry Bag
- 1 x Comprehensive Technical Operating Manual
SPECIFICATIONS
| Brand | Cabac |
| SKU | C2010 |
| Primary Diagnostic Focus | High-Accuracy AC Leakage Current Detection & Electrical Auditing |
| Maximum Current Capacity | 600 Amps AC Scope |
| Low-Range Resolution | Low mA Current Sensitivity Threshold |
| Target Infrastructure Profile | Earth Conductors & General Leakage Current Paths |
| Signal Processing Filter | Low Pass Filter (LPF) for Pure Voltage Measurement |
| Thermal Sensing Format | Temperature Type-K Thermocouple Interface |
| Duty Cycle Range Matrix | 0.1% to 99.9% Testing Scope |
| Safety Compliance Ratings | IEC61010-1 Certified | CATIII 600V Industry Standard | C-tick Approved |
| Automation Routine Profile | Auto-Ranging and Manual Ranging Selection Core |
| Display Panel Interface | 3 1/2 Digit Backlight LCD Screen |
| Display Resolution Count | 3999 Count Max Display Registry |
| Circuit Component Validation | Continuity Test with Audible Buzzer | Integrated Diode Check |
| Data Handling Functions | Max Recording Mode | Relative Measurement | Screen Data Hold |
| Power Requirements | 3 x AAA Standard Battery Cells |
| Compatible Lead System | AL28-1 Spare Leads Part Code Allocation |
| Instrument Net Weight | Approximately +400g Total Tool Mass |
| Physical Machine Dimensions | 260 mm Long x 92 mm Wide x 55 mm Thick (L260 x W92 x T55MM) |
| Primary Shipping Configuration | Supplied in Individual Commercial Gift Box |
The contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and/or any other parameters of the item/s and/or product/s and/or system/s supplied by the Company, may vary materially from those outlined by the Company.
All brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.
ALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND/OR UTILISING A GIVEN PRODUCT.
ADDITIONAL RESOURCES
PRODUCT BROCHURE
General information about the Cabac Leakage Clamp Meter to 600A is mapped out in the brochure below.
DOWNLOAD