The Uni-T UT208B True RMS Digital Clamp Meter is an industrial-grade, high-performance electrical testing instrument meticulously engineered for professional electricians, HVAC/R technicians, and heavy motor service experts operating in demanding environments. Conforming to rigorous CAT III 1000V and CAT IV 600V safety specifications and certified by CE/ETL, this comprehensive clamp meter boasts a large forty-two millimeter jaw opening and a high-contrast six thousand count LCD screen. Outfitted with premium operational features—such as a LoZ low-impedance testing mode to eradicate ghost voltage, a low pass filter (LPF ACV) configuration for high-accuracy variable frequency drive measurements, and a dedicated high-speed transient Inrush current mode—this rugged tool also supports high-resolution temperature testing and an optional flexible probe configuration to extend current measuring capacities up to three thousand Amps.
Vendor: Uni-T
Available
KEY FEATURES
- True RMS signal calculation ensures premium accuracy across noisy networks and non-linear waveforms.
- Measures high-capacity AC and DC current limits up to 1000A with integrated auto-ranging.
- Generous 42mm jaw opening diameter safely accommodates heavy commercial conductors.
- LoZ low-impedance input mode eliminates deceptive ghost voltage variables inside active panels.
- Integrated LPF ACV filter blocks high-frequency noise for accurate VFD and inverter validation.
- Transient Inrush current mode captures initial high-load motor startup surges effortlessly.
- High-precision temperature monitoring infrastructure covers a broad spectrum from -40°C to 1000°C.
- Conforms to elite safety guidelines certified up to CAT III 1000V and CAT IV 600V criteria.
The Uni-T UT208B True RMS Digital Clamp Meter delivers a highly effective and robust electrical verification framework for auditing commercial plant machinery, inspecting high-output HVAC-R compressors, and executing safe preventative maintenance building surveys. Traditional entry-level maintenance multimeters lack specialized frequency-attenuation loops, resulting in skewed calculations when reading variable frequency drives, and struggle to record fast motor starting surges; by embedding integrated low pass filters directly alongside transient current capture registries, this rugged tool ensures continuous, error-free diagnostics. Field engineers can perform expansive multi-point safety profiling across raw facility boundaries, relying on automated hardware protection and flexible input modes to preserve delicate target circuits.
ADDITIONAL FEATURES
- Supports an optional flexible current probe configuration to expand alternating current tracking ranges up to 3000A.
- Fast digital sampling core yields 3 measurement updates per second, mirrored by an active 31-segment analog bar graph trend tracker.
- High-capacity resistance checking matrix tests grounding links and line elements up to 60 Mega Ohms.
- Capacitance diagnostic core safely evaluates motor start and run capacitor banks up to 60 millifarads.
- Integrated user elements feature a dedicated flashlight button and high-visibility screen backlight for dark spaces.
- Smart data handling profile equips independent Max/Min tracking, relative mode configurations, and data hold parameters.
- Advanced power conservation framework limits wake-up sleep currents to less than 50 microamps during inactivity.
APPLICATIONS
- Perfectly optimized for True RMS AC/DC high-current clamping, variable frequency drive LPF auditing, low-impedance LoZ ghost voltage suppression, motor Inrush current capturing, high-precision point-contact temperature profiling, industrial capacitor validation, and safety-compliant facility engineering.
PRODUCT PACKAGE INCLUDES
- 1 x Uni-T UT208B True RMS Digital Clamp Meter (SKU: UT208B)
- 1 x Premium Electrical Test Leads Set
- 1 x Point-Contact Temperature Thermocouple Probe
- 3 x Standard 1.5V AAA Operational Batteries (R03)
- 1 x Soft Protective Fabric Carrying Bag
- 1 x Comprehensive English Technical Instruction Manual
SPECIFICATIONS
| Brand | Uni-T |
| SKU | UT208B |
| Primary System Profile | Professional True RMS AC/DC Industrial Diagnostics Clamp Meter |
| Alternating Current (AC A) Range | 1000A Maximum | ±(2% + 5) Stated Base Accuracy |
| AC Current Frequency Response | 40Hz to 400Hz Operational Spectrum |
| Direct Current (DC A) Range | 1000A Maximum | ±(2% + 5) Stated Base Accuracy |
| Inrush Current (AC A) Scope | 1000A Maximum Transient | ±(10% + 10) Capture Accuracy |
| Alternating Voltage (AC V) Range | 6V [±(1.2% + 3)] | 60V / 600V / 1000V [±(1% + 8)] Maximum |
| AC Voltage Frequency Response | 40Hz to 400Hz Operational Spectrum |
| Direct Voltage (DC V) Range | 600mV [±(0.8% + 3)] | 6V / 60V / 600V / 1000V [±(0.5% + 5)] Maximum |
| Low Pass Filter (LPF ACV) Range | 600V / 1000V | ±(2% + 5) Noise Attenuation Matrix |
| LoZ Low-Impedance ACV Range | 600V / 1000V | ±(2% + 5) Ghost Voltage Mitigation |
| Resistance (Ω) Measurement Scope | 600Ω [±(1%+3)] | 6kΩ to 600kΩ [±(1%+2)] | 6MΩ to 60MΩ [±(2%+8)] |
| Capacitance (F) Measurement Scope | 60nF [±(4%+25)] | 600nF to 600μF [±(4%+5)] | 6mF to 60mF [±(10%+9)] |
| Temperature Testing Range | -40℃ to 300℃ [±(1% + 20)] | 300℃ to 1000℃ [±(1% + 2)] |
| Low Voltage Frequency Range | 10Hz to 1MHz | ±(0.1% + 3) Stated Base Accuracy |
| Duty Cycle Range Matrix | 10% to 90% Scope | ±(2.6% + 7) Precision Boundary |
| Signal Calculation Core | True RMS Processing Array |
| Safety Compliance Ratings | Conforms to CAT III 1000V / CAT IV 600V | CE / ETL Certified |
| Clamp Mechanism Opening | 42mm Maximum Internal Jaw Clearance |
| Display Panel Interface | 43mm x 45mm Large LCD Screen with Dynamic Backlight |
| Display Resolution Count | 6000 Count Max Display Scale |
| Analog Trend Tracking Bar | Integrated 31-Segment Active Analog Bar Graph |
| Data Refresh Sampling Speed | Digital Screen: 3 Times / Second Nominal Refresh Rate |
| Circuit Component Validation | Continuity Beeper Sounder | Built-in Diode Testing Loop |
| Data Handling Functions | MAX / MIN Capture | Relative Mode | Data Hold | Zero Mode |
| Input Impedance Threshold | ≥10MΩ High Resistance Isolation Protection (ACV/DCV) |
| Extended Current Scaling | Flexible Current Probe Support (Optional Access up to 3000A) |
| Automated Power Mitigation | Auto Power Off (APO) <50μA Sleep Current | Wake-up/Sleep Modes |
| Power Requirements | 3 x 1.5V AAA Standard Battery Cells (R03) |
| Chassis Material Coloring | Industrial Distinct Red and Grey Accent Pattern |
| Instrument Net Weight | 420g Solid Net Tool Body |
| Physical Machine Dimensions | 272mm x 81mm x 43.5mm Total Structural Frame |
The contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and/or any other parameters of the item/s and/or product/s and/or system/s supplied by the Company, may vary materially from those outlined by the Company.
All brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.
ALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND/OR UTILISING A GIVEN PRODUCT.
ADDITIONAL RESOURCES
PRODUCT BROCHURE
General information about the Uni-T UT208B True RMS Digital Clamp Meter is mapped out in the brochure below.
DOWNLOAD