Hach TU5300sc Laser Turbidimeter with Flow Sensor, RFID, System Check, SC200 Controller, 2 Channel
Hach TU5300sc Laser Turbidimeter with Flow Sensor, RFID, System Check, SC200 Controller, 2 Channel
The ISO compliant TU5 Series platform employs a unique optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimising variability between measurements.
Vendor: Hach
Available
KEY FEATURES
- Groundbreaking 360° x 90° Detection Technology
- Matching lab and online results
- Everything about turbidity – faster
The ISO compliant TU5 Series platform employs a unique optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimising variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection Technology in any TU5 Series turbidimeter.
The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. An automatic cleaning module is available that keeps your instrument clean, reducing the amount of time spent cleaning the instrument ever further. All of this, along with the ability to measure to 2 mNTU, gives you the next standard in the evolution of turbidity.
Only the new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.
ADDITIONAL FEATURES
- Delivering the best low level precision and sensitivity while minimizing variability from test to test
- Sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab
- A smaller online sample volume means you will detect events almost immediately.
APPLICATIONS
- Water testing and treatment
PRODUCT PACKAGE INCLUDES
- Hach TU5300sc Laser Turbidimeter
- Automatic Cleaning Unit
- User Manual
- Wall Mount
- Vial Replacement Tool
- Screw Set
- Drying Cartridge
- Flow Regulator
- Service Bracket
- Flow Sensor
- SC200 Controller
SPECIFICATIONS
Brand | Hach |
Weight | 5,000 g |
Length | xx mm |
Width | xx mm |
Depth | xx mm |
Accuracy | ±2% of reading plus 0.01 NTU from 0 - 40 NTU ±10% of reading from 40 - 1000 NTU based on Formazin primary standard |
Cable Length | 1.6 m, extendable up to 50 m for instrument without accessories |
Calibration Method |
For Formazin and Stablcal: Custom calibration for up to 6-point calibrations |
Certifications |
CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Australian ACMA Marking |
Channels | 2 |
Communication | System Check & RFID |
Compliance | ISO |
Controller | 2 Channel, 100-240V AC |
Enclosure Rating | Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc instrument |
Fitting Type | Sample quick connector: ¼-in. for ¼-in. tubing |
Instrument | With flow and cleaning |
Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
Lower Limit of Detection (LOD) | 0.002 NTU |
Material |
ASA Luran S 777K / RAL7000, TPE RESIN Elastocon STK40, Thermoplastic Elastomer TPS-SEBS |
Operating Humidity | Relative humidity: 5 - 95% at different temperatures, non-condensing |
Operating temperature range | 0 - 50 °C |
Range |
ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 250 EBC |
Repeatability | Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater |
Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC |
Response time | T90 <45 seconds at 100 mL/min |
Sample Flow Rate | 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min |
Sample Temperature | 2 to 60 °C (35 to 140 °F) |
Signal Average Time | 30 to 90 seconds |
Stray Light | <10 mNTU |
Verification | Liquid: Stablcal, Formazin (0.1 - 40 NTU) Dry: Glass Rod at <0.1 NTU |
The contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and/or any other parameters of the item/s and/or product/s and/or system/s supplied by the Company, may vary materially from those outlined by the Company.
All brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.
ALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND/OR UTILISING A GIVEN PRODUCT.
ADDITIONAL RESOURCES
PRODUCT BROCHURE
Additional information about the Hach TU5300sc Laser Turbidimeter, is outlined in the Hach TU5 Series Turbidimeters brochure.
USER MANUAL
Instructions for the Hach TU5300sc Laser Turbidimeter are outlined in the HachTU5300sc Laser Turbidimeter instruction manual.