HR60 UV Disinfection System with 304 SS Reactor Chamber, Standard Ballast, 3.8 LPM

HR60 UV Disinfection System with 304 SS Reactor Chamber, Standard Ballast, 3.8 LPM

Product Code: AQU-UVHR60-304-SB

The HR60 UV Disinfection System is a proven design for the reliable, efficient and cost-effective disinfection of water, without the requirement for process heat or dangerous chemicals. The HR60 UV Disinfection System uses 254nm germicidal ultra violet (UV) light.

$210.00 Excl. GST
$231.00 Incl. GST
In Stock - Available for Fast Delivery
Vendor: Aquacorp

Available

KEY FEATURES
  • High quality stainless steel (304) UV reactor chamber
  • No moving parts and no chemicals ensures low maintenance requirements
  • Simple installation with standard 1/4" BSP plumbing fittings

 

The HR60 UV Disinfection System is a proven design for the reliable, efficient and cost-effective disinfection of water, without the requirement for process heat or dangerous chemicals. The HR60 UV Disinfection System uses 254nm germicidal ultra violet (UV) light to quickly and reliably disable bacteria, viruses and other micro organisms present in common water supplies. UV disinfection systems are a desirable form of water disinfection, as they do not do not leave residual taste or odour in treated water.

It should be noted that the rated flow rate of 3.8 LPM is based on delivering an effective UV dosage of >30 mJ/cm² @ UVT.

 

ADDITIONAL FEATURES
  • Supplied as a complete package with mounting clips and ballast
  • Ballast design incorporates an audible lamp fail alarm

 

APPLICATIONS
  • Suitable for broad range of small-scale water treatment related applications where UV disinfection is required, including health clinics, domestic potable water, low flow single outlet, aquaculture, including aquariums.

 

PRODUCT PACKAGE INCLUDES
  • HR60 UV Disinfection System with 304 SS Reactor Chamber (including UV lamp), standard ballast (with audible alarm), quartz thimble & O-ring and mounting clips

 

    Brand Aquacorp
    UV System Dimensions 
    Weight  xxx g
    Length 280 mm
    Width 45 mm
    Depth 53 mm
    Inlet/Outlet Fitting Size 1/4" BSPF / 1/4 Quick Fit Tube
    Power Requirements 240 V AC 10 amp
    Lamp Wattage 10 W
    Feedwater Requirements The UV system requires minimum water quality for correct disinfection. Pre-treatment must be considered if the raw water supply does not meet the following minimum requirements.
    Turbidity < 1 NTU (5 micron filtration recommended)
    Operating Temperature 0°C - 40°C 
    Operating Pressure 690 kPa (100psi) max
    Chloride (Cl) < 500 mg/L
    Hardness (CaCO3) < 120 mg/L
    Iron (Fe) < 0.3 mg/L
    Manganese (Mn) < 0.05 mg/L

     

    The contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, perforfmance and/or any other parameters of the item/s and/or product/s and/or system/s supplied by the Company, may vary materially from those outlined by the Company.


    All brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.


    ALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND/OR UTILISING A GIVEN PRODUCT.


     

    PRODUCT INFORMATION SHEET (PIS)

    Additional information about the 1HR60 UV Disinfection System, is outlined in the HR60 UV Disinfection System, product information sheet (PIS).

    DOWNLOAD

    KEY FEATURES
    • High quality stainless steel (304) UV reactor chamber
    • No moving parts and no chemicals ensures low maintenance requirements
    • Simple installation with standard 1/4" BSP plumbing fittings

     

    The HR60 UV Disinfection System is a proven design for the reliable, efficient and cost-effective disinfection of water, without the requirement for process heat or dangerous chemicals. The HR60 UV Disinfection System uses 254nm germicidal ultra violet (UV) light to quickly and reliably disable bacteria, viruses and other micro organisms present in common water supplies. UV disinfection systems are a desirable form of water disinfection, as they do not do not leave residual taste or odour in treated water.

    It should be noted that the rated flow rate of 3.8 LPM is based on delivering an effective UV dosage of >30 mJ/cm² @ UVT.

     

    ADDITIONAL FEATURES
    • Supplied as a complete package with mounting clips and ballast
    • Ballast design incorporates an audible lamp fail alarm

     

    APPLICATIONS
    • Suitable for broad range of small-scale water treatment related applications where UV disinfection is required, including health clinics, domestic potable water, low flow single outlet, aquaculture, including aquariums.

     

    PRODUCT PACKAGE INCLUDES
    • HR60 UV Disinfection System with 304 SS Reactor Chamber (including UV lamp), standard ballast (with audible alarm), quartz thimble & O-ring and mounting clips

     

      SPECIFICATIONS
      Brand Aquacorp
      UV System Dimensions 
      Weight  xxx g
      Length 280 mm
      Width 45 mm
      Depth 53 mm
      Inlet/Outlet Fitting Size 1/4" BSPF / 1/4 Quick Fit Tube
      Power Requirements 240 V AC 10 amp
      Lamp Wattage 10 W
      Feedwater Requirements The UV system requires minimum water quality for correct disinfection. Pre-treatment must be considered if the raw water supply does not meet the following minimum requirements.
      Turbidity < 1 NTU (5 micron filtration recommended)
      Operating Temperature 0°C - 40°C 
      Operating Pressure 690 kPa (100psi) max
      Chloride (Cl) < 500 mg/L
      Hardness (CaCO3) < 120 mg/L
      Iron (Fe) < 0.3 mg/L
      Manganese (Mn) < 0.05 mg/L

       

      The contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, perforfmance and/or any other parameters of the item/s and/or product/s and/or system/s supplied by the Company, may vary materially from those outlined by the Company.


      All brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.


      ALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND/OR UTILISING A GIVEN PRODUCT.


       

      ADDITIONAL RESOURCES
      PRODUCT INFORMATION SHEET (PIS)

      Additional information about the 1HR60 UV Disinfection System, is outlined in the HR60 UV Disinfection System, product information sheet (PIS).

      DOWNLOAD

      Claritas est etiam processus dynamicus, qui sequitur mutationem consuetudium lectorum. Mirum est notare quam littera gothica, quam nunc putamus parum claram, anteposuerit litterarum formas humanitatis per seacula quarta decima et quinta decima. Eodem modo typi, qui nunc nobis videntur parum clari, fiant sollemnes in futurum.