Myron L Ultrameter III 9P Multi-Parameter Water Quality Meter AHL Titration Kit

Myron L Ultrameter III 9P Multi-Parameter Water Quality Meter AHL Titration Kit

Product Code: MYR-9PTK

The Myron L Ultrameter III 9PTK is a complete AHL titration kit for professional water quality analysis. It measures conductivity, resistivity, TDS, alkalinity, hardness, LSI, pH, ORP, free chlorine and temperature. Featuring guided in-cell titrations, an LSI Calculator, automatic temperature compensation, memory for up to 100 readings and an IP67 waterproof design, it provides accurate and convenient testing for laboratory, industrial and field applications.

$3,994.00 Excl. GST
$4,393.40 Incl. GST
In Stock - Available for Fast Delivery
Vendor: Myron L

Available

Myron L Ultrameter III 9P Multi-Parameter Water Quality Meter AHL Titration Kit is the upgraded replacement for the earlier Myron L Ultrameter II KIT.

 

KEY FEATURES
  • Fast One-Touch Measurements: Quickly measures conductivity, resistivity, TDS, ORP, free chlorine (FCE), pH and temperature.
  • Simple Guided Operation: Intuitive prompts guide users through alkalinity, hardness and LSI titrations.
  • Convenient LSI Calculator: Supports hardness measurements in both grains and ppm.
  • Easy Calibration: User-friendly keypad enables quick and straightforward calibration.
  • Stable 4-Electrode Conductivity Cell: Minimises polarisation for improved accuracy and reduced maintenance.
  • Powerful Microprocessor Technology: Advanced microprocessor-based circuitry provides reliable performance.

 

The Myron L Ultrameter III 9PTK AHL Titration Kit is a professional, portable water quality testing solution designed for fast and accurate field analysis. The Ultrameter III 9P provides one-touch measurement of conductivity, resistivity, TDS, ORP, free chlorine (FCE), pH and temperature, while built-in conductometric titration functions allow users to determine alkalinity, hardness and Langelier Saturation Index (LSI).

Designed for simple operation, the 9P uses intuitive display prompts to guide users through alkalinity, hardness and LSI titrations. Its LSI Calculator also allows users to assess water balance and predict how changes in water parameters may affect whether a solution is balanced, scaling or corrosive.

The instrument features a stable four-electrode conductivity cell, user-replaceable pH/ORP sensor, automatic temperature compensation and selectable solution modes for KCl, NaCl and 442 Natural Water. A rugged IP67/NEMA 6 waterproof and buoyant housing makes it suitable for laboratory, industrial plant and field applications. It can store up to 100 readings, while the 9V battery provides more than 100 hours or approximately 5,000 readings of operation.

 

ADDITIONAL FEATURES
  • Replaceable pH/ORP Sensor: Unique glass pH/ORP sensor can be replaced by the user.
  • Versatile Solution Modes: Provides accurate measurements across a wide range of water quality applications.
  • Efficient Power Management: Auto-off function reduces power consumption, with one 9V battery providing up to 100 hours or approximately 5,000 tests.
  • Advanced Compensation: Proprietary temperature compensation and TDS conversion algorithms enhance measurement accuracy.
  • Reliable Data Retention: Non-volatile memory retains calibration settings and stored data even when the battery is replaced.

 

APPLICATIONS
  • Water treatment, drinking water testing, industrial process water, municipal water monitoring, cooling and boiler water, pools and spas, reverse osmosis systems, environmental water testing, field analysis and general water quality assessment.

 

PRODUCT PACKAGE INCLUDES
  • Ultrameter III 9P meter
  • Cell extender
  • Titration plunger
  • 100 μL pipette
  • 12 pipette tips
  • pH 4 buffer solution – 59 mL
  • pH 7 buffer solution – 59 mL
  • pH 10 buffer solution – 59 mL
  • pH/ORP Sensor Storage Solution – 59 mL
  • ORP Conditioner Solution – 59 mL
  • H₂SO₄-1 titration reagent – 59 mL
  • HCl-3 titration reagent – 59 mL
  • NaOH titration reagent – 59 mL
  • EDTA-LC titration reagent – 59 mL
  • EDTA-HC titration reagent – 59 mL
  • Alkalinity Standard 100 – 59 mL
  • Hardness Standard 200 – 59 mL
  • KCl-7000 standard solution – 59 mL
  • 442-3000 standard solution – 59 mL

 

    Specification Details
    Brand Myron L
    Display 4-digit LCD
    Conductivity Range 0–9999 µS/cm; 10–200 mS/cm, 5 autoranges
    TDS Range 0–9999 ppm; 10–200 ppt, 5 autoranges
    Resistivity Range 10 kΩ–30 MΩ
    pH Range 0–14 pH
    ORP Range ±999 mV
    Free Chlorine Range 0.00–9.99 ppm
    Alkalinity Titration Range 10–800 ppm
    Hardness Titration Range 0–1710 ppm / 0–100 grains
    LSI Range -10 to +10
    Temperature Range 0–71°C / 32–160°F
    Conductivity Accuracy ±1% of reading
    TDS Accuracy ±1% of reading
    Resistivity Accuracy ±1% of reading
    pH Accuracy ±0.01 pH
    ORP Accuracy ±1 mV
    Temperature Accuracy ±0.1°C
    Memory Up to 100 readings
    Dimensions (L × W × H) 196 × 68 × 64 mm
    Weight 352 g
    Case Material VALOX
    Conductivity/TDS Electrodes 316 stainless steel
    Conductivity/TDS Cell Capacity 5 mL
    pH/ORP Sensor Well Capacity 1.2 mL
    Power Supply 9V alkaline battery
    Battery Life >100 hours / approximately 5,000 readings
    Operating/Storage Temperature 0–55°C
    Protection Rating IP67 / NEMA 6; waterproof to 1 m
    Wireless Connectivity Optional Bluetooth via bluDock accessory

     

    The contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and/or any other parameters of the item/s and/or product/s and/or system/s supplied by the Company, may vary materially from those outlined by the Company.


    All brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.


    ALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND/OR UTILISING A GIVEN PRODUCT.


     

    PRODUCT INFORMATION SHEET (PIS)

    Additional information about the Myron L Ultrameter III 9PTK AHL Titration Kit, is outlined in the product information sheet.

    DOWNLOAD

     

    USER MANUAL

    Instructions for the Myron L Ultrameter III 9PTK AHL Titration Kit is outlined in the Instruction Manual.

    DOWNLOAD

    Myron L Ultrameter III 9P Multi-Parameter Water Quality Meter AHL Titration Kit is the upgraded replacement for the earlier Myron L Ultrameter II KIT.

     

    KEY FEATURES
    • Fast One-Touch Measurements: Quickly measures conductivity, resistivity, TDS, ORP, free chlorine (FCE), pH and temperature.
    • Simple Guided Operation: Intuitive prompts guide users through alkalinity, hardness and LSI titrations.
    • Convenient LSI Calculator: Supports hardness measurements in both grains and ppm.
    • Easy Calibration: User-friendly keypad enables quick and straightforward calibration.
    • Stable 4-Electrode Conductivity Cell: Minimises polarisation for improved accuracy and reduced maintenance.
    • Powerful Microprocessor Technology: Advanced microprocessor-based circuitry provides reliable performance.

     

    The Myron L Ultrameter III 9PTK AHL Titration Kit is a professional, portable water quality testing solution designed for fast and accurate field analysis. The Ultrameter III 9P provides one-touch measurement of conductivity, resistivity, TDS, ORP, free chlorine (FCE), pH and temperature, while built-in conductometric titration functions allow users to determine alkalinity, hardness and Langelier Saturation Index (LSI).

    Designed for simple operation, the 9P uses intuitive display prompts to guide users through alkalinity, hardness and LSI titrations. Its LSI Calculator also allows users to assess water balance and predict how changes in water parameters may affect whether a solution is balanced, scaling or corrosive.

    The instrument features a stable four-electrode conductivity cell, user-replaceable pH/ORP sensor, automatic temperature compensation and selectable solution modes for KCl, NaCl and 442 Natural Water. A rugged IP67/NEMA 6 waterproof and buoyant housing makes it suitable for laboratory, industrial plant and field applications. It can store up to 100 readings, while the 9V battery provides more than 100 hours or approximately 5,000 readings of operation.

     

    ADDITIONAL FEATURES
    • Replaceable pH/ORP Sensor: Unique glass pH/ORP sensor can be replaced by the user.
    • Versatile Solution Modes: Provides accurate measurements across a wide range of water quality applications.
    • Efficient Power Management: Auto-off function reduces power consumption, with one 9V battery providing up to 100 hours or approximately 5,000 tests.
    • Advanced Compensation: Proprietary temperature compensation and TDS conversion algorithms enhance measurement accuracy.
    • Reliable Data Retention: Non-volatile memory retains calibration settings and stored data even when the battery is replaced.

     

    APPLICATIONS
    • Water treatment, drinking water testing, industrial process water, municipal water monitoring, cooling and boiler water, pools and spas, reverse osmosis systems, environmental water testing, field analysis and general water quality assessment.

     

    PRODUCT PACKAGE INCLUDES
    • Ultrameter III 9P meter
    • Cell extender
    • Titration plunger
    • 100 μL pipette
    • 12 pipette tips
    • pH 4 buffer solution – 59 mL
    • pH 7 buffer solution – 59 mL
    • pH 10 buffer solution – 59 mL
    • pH/ORP Sensor Storage Solution – 59 mL
    • ORP Conditioner Solution – 59 mL
    • H₂SO₄-1 titration reagent – 59 mL
    • HCl-3 titration reagent – 59 mL
    • NaOH titration reagent – 59 mL
    • EDTA-LC titration reagent – 59 mL
    • EDTA-HC titration reagent – 59 mL
    • Alkalinity Standard 100 – 59 mL
    • Hardness Standard 200 – 59 mL
    • KCl-7000 standard solution – 59 mL
    • 442-3000 standard solution – 59 mL

     

      SPECIFICATIONS
      Specification Details
      Brand Myron L
      Display 4-digit LCD
      Conductivity Range 0–9999 µS/cm; 10–200 mS/cm, 5 autoranges
      TDS Range 0–9999 ppm; 10–200 ppt, 5 autoranges
      Resistivity Range 10 kΩ–30 MΩ
      pH Range 0–14 pH
      ORP Range ±999 mV
      Free Chlorine Range 0.00–9.99 ppm
      Alkalinity Titration Range 10–800 ppm
      Hardness Titration Range 0–1710 ppm / 0–100 grains
      LSI Range -10 to +10
      Temperature Range 0–71°C / 32–160°F
      Conductivity Accuracy ±1% of reading
      TDS Accuracy ±1% of reading
      Resistivity Accuracy ±1% of reading
      pH Accuracy ±0.01 pH
      ORP Accuracy ±1 mV
      Temperature Accuracy ±0.1°C
      Memory Up to 100 readings
      Dimensions (L × W × H) 196 × 68 × 64 mm
      Weight 352 g
      Case Material VALOX
      Conductivity/TDS Electrodes 316 stainless steel
      Conductivity/TDS Cell Capacity 5 mL
      pH/ORP Sensor Well Capacity 1.2 mL
      Power Supply 9V alkaline battery
      Battery Life >100 hours / approximately 5,000 readings
      Operating/Storage Temperature 0–55°C
      Protection Rating IP67 / NEMA 6; waterproof to 1 m
      Wireless Connectivity Optional Bluetooth via bluDock accessory

       

      The contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and/or any other parameters of the item/s and/or product/s and/or system/s supplied by the Company, may vary materially from those outlined by the Company.


      All brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.


      ALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND/OR UTILISING A GIVEN PRODUCT.


       

      ADDITIONAL RESOURCES
      PRODUCT INFORMATION SHEET (PIS)

      Additional information about the Myron L Ultrameter III 9PTK AHL Titration Kit, is outlined in the product information sheet.

      DOWNLOAD

       

      USER MANUAL

      Instructions for the Myron L Ultrameter III 9PTK AHL Titration Kit is outlined in the Instruction Manual.

      DOWNLOAD

      Claritas est etiam processus dynamicus, qui sequitur mutationem consuetudium lectorum. Mirum est notare quam littera gothica, quam nunc putamus parum claram, anteposuerit litterarum formas humanitatis per seacula quarta decima et quinta decima. Eodem modo typi, qui nunc nobis videntur parum clari, fiant sollemnes in futurum.