{"product_id":"uni-t-ut219m-professional-clamp-meter-motor-test-loz","title":"Uni-T UT219M Professional Clamp Meter Motor Test Loz","description":"\u003ch6\u003eKEY FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS signal processing guarantees highly accurate metrics across distorted or non-linear electrical waveforms.\u003c\/li\u003e\n\u003cli\u003eAdvanced motor diagnostics incorporate a specialized 600V 3-phase motor sequence testing routine.\u003c\/li\u003e\n\u003cli\u003eLoZ low-impedance input mode actively suppresses and eliminates deceptive ghost voltage variables.\u003c\/li\u003e\n\u003cli\u003eDual AC\/DC microamp (µA) current configurations verify heating system flame rectifiers up to 2000µA.\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade build with an IP54 protection class rating to repel ambient dust and splashing water.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty ruggedized composite chassis certified to withstand a 2-meter physical drop test protocol.\u003c\/li\u003e\n\u003cli\u003eGenerous 33mm internal jaw opening diameter safely accommodates standard industrial cables.\u003c\/li\u003e\n\u003cli\u003eHigh-contrast 6000-count single LCD display features an automated screen auto-backlight and built-in flashlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Uni-T UT219M Professional Clamp Meter Motor Test Loz delivers a highly effective and robust electrical verification framework for auditing commercial plant systems, testing variable-speed blowers, and diagnosing complex industrial motor networks. Standard entry-level multimeters lack the strict overvoltage insulation barriers and structural drop damping required for high-risk jobsites, leading to damaged internal components or incorrect data tracking; by surrounding this high-purity processor in a hardened housing rated for CAT III 1000V and CAT IV 600V safety zones, it ensures ultimate baseline stability. Field mechanics can perform extensive multi-point safety profiling across raw facility boundaries, relying on high input impedance and automatic parameter selection to take control of noisy machinery lines without introducing manual reading errors.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eADDITIONAL FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eSupplied K-type contact temperature thermocouple probe array records wide environmental thermal fields.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity capacitance core safely tests and evaluates motor start and run capacitor banks up to 60 millifarads.\u003c\/li\u003e\n\u003cli\u003eWide resistance testing threshold tracks grounding networks and line elements accurately up to 60 Mega Ohms.\u003c\/li\u003e\n\u003cli\u003eFast digital sampling matrix updates screen parameters at 3 measurement updates per second.\u003c\/li\u003e\n\u003cli\u003eSmart data handling profile equips independent Max\/Min tracking, relative modes (REL), zero mode, and data hold.\u003c\/li\u003e\n\u003cli\u003eAutomated power saving framework triggers an auto power-off sequence to preserve battery cell life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eAPPLICATIONS\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003ePerfectly optimized for industrial AC current clamping, True RMS electrical voltage testing, 3-phase motor sequence checking, low-impedance LoZ ghost voltage mitigation, flame sensor microamps diagnostics, contact temperature profiling, circuit capacitance validation, and professional HVAC\/R safety auditing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePRODUCT PACKAGE INCLUDES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Uni-T UT219M Professional Heavy-Duty Motor Clamp Meter (SKU: UT219M)\u003c\/li\u003e\n\u003cli\u003e1 x Premium Electrical Test Leads Set (1-Meter)\u003c\/li\u003e\n\u003cli\u003e1 x Point-Contact K-Type Temperature Thermocouple Probe (80-Centimeter)\u003c\/li\u003e\n\u003cli\u003e3 x Standard 1.5V AAA Operational Batteries\u003c\/li\u003e\n\u003cli\u003e1 x Soft Protective Fabric Travel Carrying Bag \/ Pouch\u003c\/li\u003e\n\u003cli\u003e1 x Comprehensive English Technical User Instruction Manual\u003c\/li\u003e\n\u003cli\u003e1 x 12-Month Official Factory Warranty Certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eUni-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eUT219M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary System Profile\u003c\/td\u003e\n\u003ctd\u003eProfessional Heavy-Duty Industrial Electrical \u0026amp; Motor Diagnostics Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Current (AC A) Range Scope\u003c\/td\u003e\n\u003ctd\u003e60A \/ 600A | ±(1.8% + 6) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz to 400Hz Operational Spectrum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Voltage (AC V) Range Scope\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V | ±(1.0% + 6) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz to 400Hz Operational Spectrum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Voltage (DC V) Range Scope\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V | ±(0.6% + 3) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoZ Low-Impedance ACV Range\u003c\/td\u003e\n\u003ctd\u003e600V Maximum | ±(2.5% + 6) Ghost Voltage Suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Current Microamps (DC µA)\u003c\/td\u003e\n\u003ctd\u003e2000µA Maximum | ±(0.9% + 6) Flame Sensor Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Current Microamps (AC µA)\u003c\/td\u003e\n\u003ctd\u003e2000µA Maximum | ±(1.5% + 6) Flame Sensor Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω) Measurement Scope\u003c\/td\u003e\n\u003ctd\u003e60Ω [±(1.5%+3)] | 600Ω to 60MΩ [±(1.0%+3)] Maximum Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement Scope\u003c\/td\u003e\n\u003ctd\u003e6nF [±(4.0%+7)] | 60nF to 60mF [±(4.0%+7)] Maximum Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Extraction Range Scope\u003c\/td\u003e\n\u003ctd\u003e60Hz to 40MHz | ±(0.1% + 6) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Testing Range (Celsius)\u003c\/td\u003e\n\u003ctd\u003e-40°C to 1000°C | ±(2.0% + 5°C) Stated Accuracy Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Testing Range (Fahrenheit)\u003c\/td\u003e\n\u003ctd\u003e-40°F to 1832°F | ±(2.0% + 9°F) Stated Accuracy Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Calculation Core\u003c\/td\u003e\n\u003ctd\u003eTrue RMS Processing Array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance Ratings\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V \/ CAT IV 600V Certified Instrument Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection Class\u003c\/td\u003e\n\u003ctd\u003eIP54 Ingress Dust \u0026amp; Splash Certified Waterproof Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Structural Endurance\u003c\/td\u003e\n\u003ctd\u003e2-Meter (2m) Drop-Proof Drop Test Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Mechanism Opening\u003c\/td\u003e\n\u003ctd\u003e33mm Internal Jaw Diameter Clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel Interface\u003c\/td\u003e\n\u003ctd\u003e35mm x 31mm High-Contrast LCD (HTN) Screen with Auto Backlight \u0026amp; Flashlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution Count\u003c\/td\u003e\n\u003ctd\u003e6000 Count Max Display Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Sampling Speed\u003c\/td\u003e\n\u003ctd\u003eDigital Screen: 3 Times \/ Second Nominal Refresh Rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Component Validation\u003c\/td\u003e\n\u003ctd\u003e3V Maximum Diode Test Matrix | Continuity Testing Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Handling Functions\u003c\/td\u003e\n\u003ctd\u003eMAX \/ MIN Capture | Relative Mode (REL) | Data Hold (H) | ZERO Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance Threshold\u003c\/td\u003e\n\u003ctd\u003e≥10MΩ High Resistance Isolation Protection Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5V AAA Standard Alkaline Battery Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Material Coloring\u003c\/td\u003e\n\u003ctd\u003eIndustrial Distinct Red and Grey Accent Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Net Weight\u003c\/td\u003e\n\u003ctd\u003e310g Solid Net Tool Body Mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Machine Dimensions\u003c\/td\u003e\n\u003ctd\u003e235mm Long x 82mm Wide x 47mm Thick (235mm x 82mm x 47mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Warranty Term\u003c\/td\u003e\n\u003ctd\u003e12-Month Official Coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and\/or any other parameters of the item\/s and\/or product\/s and\/or system\/s supplied by the Company, may vary materially from those outlined by the Company.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAll brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND\/OR UTILISING A GIVEN PRODUCT.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eADDITIONAL RESOURCES\u003c\/h5\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT BROCHURE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eGeneral information about the Uni-T UT219M Professional Clamp Meter is mapped out in the brochure below.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/4325\/8421\/files\/353083EN-C.pdf?v=1777340118\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":50272392380653,"sku":"UNI-UT219M","price":236.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/9529\/3345\/files\/UT219M-01.jpg?v=1783917281","url":"https:\/\/pwnps.com\/products\/uni-t-ut219m-professional-clamp-meter-motor-test-loz","provider":"Parkway Process Solutions","version":"1.0","type":"link"}