{"product_id":"uni-t-ut219ds-professional-clamp-meter","title":"Uni-T UT219DS Professional Clamp Meter","description":"\u003ch6\u003eKEY FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial-grade build with an IP54 protection class rating to safeguard against dust and water ingress.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty ruggedized composite housing certified to survive a 2-meter physical drop test.\u003c\/li\u003e\n\u003cli\u003eTrue RMS signal processing guarantees highly accurate metrics across distorted or noisy waves.\u003c\/li\u003e\n\u003cli\u003eV+A dual LCD display screen permits parallel monitoring of voltage and current variables at the same time.\u003c\/li\u003e\n\u003cli\u003eAdvanced motor diagnostics include transient Inrush current capturing and a 600V 3-phase sequence test.\u003c\/li\u003e\n\u003cli\u003eIntegrated 1kHz low pass filter provides clean variable frequency drive (VFD) output readings.\u003c\/li\u003e\n\u003cli\u003eLoZ low-impedance input mode actively suppresses and eliminates deceptive ghost voltage variables.\u003c\/li\u003e\n\u003cli\u003eDedicated microamp (µA) current testing functionality allows quick troubleshooting of heating system flame sensors.\u003c\/li\u003e\n\u003cli\u003eBuilt-in point-contact temperature probe array records wide environmental thermal fields.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Uni-T UT219DS Professional Clamp Meter delivers a highly effective and robust electrical verification framework for auditing commercial plant systems, profiling variable-speed blowers, and diagnosing complex industrial motor networks. Standard consumer-grade diagnostic multimeters lack the strict safety insulation barriers and structural drop damping required for high-risk jobsites, leading to damaged internal components or inaccurate reading tracking; by surrounding this high-purity processor in a hardened housing rated for CAT III 1000V and CAT IV 600V safety zones, it ensures ultimate baseline stability. Field technicians can manage intensive industrial power inspections confidently, tracking fast transient loads with a swift 5 times per second digital refresh speed while relying on automated hardware protection loops.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eADDITIONAL FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eFast digital sampling matrix updates screen parameters at 5 times\/s, backed by a 31-segment analog bar graph refreshing at 20 times\/s.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity capacitance core safely tests and evaluates motor start\/run elements up to 60 millifarads.\u003c\/li\u003e\n\u003cli\u003eIntegrated convenience tools include an on-board flashlight and an automated screen auto-backlight sensory module.\u003c\/li\u003e\n\u003cli\u003eDual range selection mechanism gives operators total control over automatic or manual range adjustments.\u003c\/li\u003e\n\u003cli\u003eSmart auto power-off (APO) framework saves battery assets by shutting down automatically after a period of inactivity.\u003c\/li\u003e\n\u003cli\u003eHigh input impedance over or equal to 10 Mega Ohms prevents unwanted circuit loading faults during critical measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eAPPLICATIONS\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003ePerfectly optimized for True RMS AC\/DC current clamping, motor Inrush current tracking, variable frequency drive low pass filtering, 3-phase motor sequence testing, flame sensor microamps diagnostics, LoZ ghost voltage mitigation, contact temperature profiling, and industrial HVAC\/R safety auditing in harsh field environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePRODUCT PACKAGE INCLUDES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Uni-T UT219DS Professional Heavy-Duty Dual Display Clamp Meter\u003c\/li\u003e\n\u003cli\u003e1 x Premium Electrical Test Leads Set\u003c\/li\u003e\n\u003cli\u003e1 x Point-Contact Temperature Thermocouple Probe\u003c\/li\u003e\n\u003cli\u003e3 x Standard 1.5V AAA Operational Batteries (R03)\u003c\/li\u003e\n\u003cli\u003e1 x Soft Protective Fabric Carrying Bag\u003c\/li\u003e\n\u003cli\u003e1 x Technical PC Software Data CD Asset\u003c\/li\u003e\n\u003cli\u003e1 x Comprehensive English Technical User Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eUni-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eUT219DS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Diagnostic Focus\u003c\/td\u003e\n\u003ctd\u003eProfessional Heavy-Duty Industrial AC\/DC Electrical \u0026amp; Motor Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Current (AC A) Range\u003c\/td\u003e\n\u003ctd\u003e600A Maximum | ±(1.8% + 6) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz to 400Hz Operational Spectrum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Current (DC A) Range\u003c\/td\u003e\n\u003ctd\u003e600A Maximum | ±(1.8% + 6) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Voltage (AC V) Range\u003c\/td\u003e\n\u003ctd\u003e600V Maximum | ±(1% + 6) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz to 1kHz Operational Spectrum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Voltage (DC V) Range\u003c\/td\u003e\n\u003ctd\u003e600V Maximum | ±(0.6% + 3) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoZ Low-Impedance ACV Range\u003c\/td\u003e\n\u003ctd\u003e600V Maximum | ±(2.5% + 6) Ghost Voltage Suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω) Measurement Scope\u003c\/td\u003e\n\u003ctd\u003eUp to 60MΩ (60 Mega Ohms) | ±(1% + 3) Stated Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance (F) Measurement Scope\u003c\/td\u003e\n\u003ctd\u003eUp to 60mF (60 Millifarads) | ±(4% + 7) Stated Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz) Extraction Range\u003c\/td\u003e\n\u003ctd\u003e10Hz to 10MHz Baseline | Extended Splay 600Hz to 40MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle Range Matrix\u003c\/td\u003e\n\u003ctd\u003e0.1% to 99.9% Scope | ±(2.6% + 7) Precision Boundary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Testing Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to 1000°C [±(2% + 5°C)] | -40°F to 1832°F [±(2% + 9°F)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Calculation Core\u003c\/td\u003e\n\u003ctd\u003eTrue RMS Processing Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Pass Filter (LPF) Profile\u003c\/td\u003e\n\u003ctd\u003e1kHz Cutoff, 3db Attenuation Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance Ratings\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V \/ CAT IV 600V Certified Instrument Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection Class\u003c\/td\u003e\n\u003ctd\u003eIP54 Dust \u0026amp; Splash Ingress Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Structural Endurance\u003c\/td\u003e\n\u003ctd\u003e2-Meter (2m) Drop-Proof Drop Test Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Mechanism Opening\u003c\/td\u003e\n\u003ctd\u003e33mm Internal Jaw Clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel Interface\u003c\/td\u003e\n\u003ctd\u003eDual High-Contrast 6000 Display Count LCD with Auto Backlight \u0026amp; Flashlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Sampling Rates\u003c\/td\u003e\n\u003ctd\u003eDigital Screen: 5 Times \/ Second | Analog Segment Bar: 20 Times \/ Second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Trend Tracking Bar\u003c\/td\u003e\n\u003ctd\u003eIntegrated 31-Segment Active Analog Bar Graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Component Validation\u003c\/td\u003e\n\u003ctd\u003e3V Maximum Diode Test Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Handling Functions\u003c\/td\u003e\n\u003ctd\u003eInrush Current | MAX \/ MIN Capture | Relative Mode (REL) | Data Hold (H) | ZERO Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance Threshold\u003c\/td\u003e\n\u003ctd\u003e≥10MΩ Standard High Resistance Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5V AAA Standard Battery Cells (R03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Material Coloring\u003c\/td\u003e\n\u003ctd\u003eIndustrial Distinct Red and Grey Accent Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Net Weight\u003c\/td\u003e\n\u003ctd\u003e310g Solid Net Tool Body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Machine Dimensions\u003c\/td\u003e\n\u003ctd\u003e234.6mm x 82mm x 47mm Total Structural Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and\/or any other parameters of the item\/s and\/or product\/s and\/or system\/s supplied by the Company, may vary materially from those outlined by the Company.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAll brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND\/OR UTILISING A GIVEN PRODUCT.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eADDITIONAL RESOURCES\u003c\/h5\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT BROCHURE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eGeneral information about the Uni-T UT219DS Professional Clamp Meter is outlined in below brochure.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":50272101630189,"sku":"UNI-UT219DS","price":284.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/9529\/3345\/files\/UT219DS-01.jpg?v=1783922056","url":"https:\/\/pwnps.com\/products\/uni-t-ut219ds-professional-clamp-meter","provider":"Parkway Process Solutions","version":"1.0","type":"link"}