{"product_id":"uni-t-ut208b-true-rms-digital-clamp-meter","title":"Uni-T UT208B True RMS Digital Clamp Meter","description":"\u003ch6\u003eKEY FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS signal calculation ensures premium accuracy across noisy networks and non-linear waveforms.\u003c\/li\u003e\n\u003cli\u003eMeasures high-capacity AC and DC current limits up to 1000A with integrated auto-ranging.\u003c\/li\u003e\n\u003cli\u003eGenerous 42mm jaw opening diameter safely accommodates heavy commercial conductors.\u003c\/li\u003e\n\u003cli\u003eLoZ low-impedance input mode eliminates deceptive ghost voltage variables inside active panels.\u003c\/li\u003e\n\u003cli\u003eIntegrated LPF ACV filter blocks high-frequency noise for accurate VFD and inverter validation.\u003c\/li\u003e\n\u003cli\u003eTransient Inrush current mode captures initial high-load motor startup surges effortlessly.\u003c\/li\u003e\n\u003cli\u003eHigh-precision temperature monitoring infrastructure covers a broad spectrum from -40°C to 1000°C.\u003c\/li\u003e\n\u003cli\u003eConforms to elite safety guidelines certified up to CAT III 1000V and CAT IV 600V criteria.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Uni-T UT208B True RMS Digital Clamp Meter delivers a highly effective and robust electrical verification framework for auditing commercial plant machinery, inspecting high-output HVAC-R compressors, and executing safe preventative maintenance building surveys. Traditional entry-level maintenance multimeters lack specialized frequency-attenuation loops, resulting in skewed calculations when reading variable frequency drives, and struggle to record fast motor starting surges; by embedding integrated low pass filters directly alongside transient current capture registries, this rugged tool ensures continuous, error-free diagnostics. Field engineers can perform expansive multi-point safety profiling across raw facility boundaries, relying on automated hardware protection and flexible input modes to preserve delicate target circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eADDITIONAL FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eSupports an optional flexible current probe configuration to expand alternating current tracking ranges up to 3000A.\u003c\/li\u003e\n\u003cli\u003eFast digital sampling core yields 3 measurement updates per second, mirrored by an active 31-segment analog bar graph trend tracker.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity resistance checking matrix tests grounding links and line elements up to 60 Mega Ohms.\u003c\/li\u003e\n\u003cli\u003eCapacitance diagnostic core safely evaluates motor start and run capacitor banks up to 60 millifarads.\u003c\/li\u003e\n\u003cli\u003eIntegrated user elements feature a dedicated flashlight button and high-visibility screen backlight for dark spaces.\u003c\/li\u003e\n\u003cli\u003eSmart data handling profile equips independent Max\/Min tracking, relative mode configurations, and data hold parameters.\u003c\/li\u003e\n\u003cli\u003eAdvanced power conservation framework limits wake-up sleep currents to less than 50 microamps during inactivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eAPPLICATIONS\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003ePerfectly optimized for True RMS AC\/DC high-current clamping, variable frequency drive LPF auditing, low-impedance LoZ ghost voltage suppression, motor Inrush current capturing, high-precision point-contact temperature profiling, industrial capacitor validation, and safety-compliant facility engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePRODUCT PACKAGE INCLUDES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Uni-T UT208B True RMS Digital Clamp Meter (SKU: UT208B)\u003c\/li\u003e\n\u003cli\u003e1 x Premium Electrical Test Leads Set\u003c\/li\u003e\n\u003cli\u003e1 x Point-Contact Temperature Thermocouple Probe\u003c\/li\u003e\n\u003cli\u003e3 x Standard 1.5V AAA Operational Batteries (R03)\u003c\/li\u003e\n\u003cli\u003e1 x Soft Protective Fabric Carrying Bag\u003c\/li\u003e\n\u003cli\u003e1 x Comprehensive English Technical Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eUni-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eUT208B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary System Profile\u003c\/td\u003e\n\u003ctd\u003eProfessional True RMS AC\/DC Industrial Diagnostics Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Current (AC A) Range\u003c\/td\u003e\n\u003ctd\u003e1000A Maximum | ±(2% + 5) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz to 400Hz Operational Spectrum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Current (DC A) Range\u003c\/td\u003e\n\u003ctd\u003e1000A Maximum | ±(2% + 5) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current (AC A) Scope\u003c\/td\u003e\n\u003ctd\u003e1000A Maximum Transient | ±(10% + 10) Capture Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Voltage (AC V) Range\u003c\/td\u003e\n\u003ctd\u003e6V [±(1.2% + 3)] | 60V \/ 600V \/ 1000V [±(1% + 8)] Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz to 400Hz Operational Spectrum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Voltage (DC V) Range\u003c\/td\u003e\n\u003ctd\u003e600mV [±(0.8% + 3)] | 6V \/ 60V \/ 600V \/ 1000V [±(0.5% + 5)] Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Pass Filter (LPF ACV) Range\u003c\/td\u003e\n\u003ctd\u003e600V \/ 1000V | ±(2% + 5) Noise Attenuation Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoZ Low-Impedance ACV Range\u003c\/td\u003e\n\u003ctd\u003e600V \/ 1000V | ±(2% + 5) Ghost Voltage Mitigation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω) Measurement Scope\u003c\/td\u003e\n\u003ctd\u003e600Ω [±(1%+3)] | 6kΩ to 600kΩ [±(1%+2)] | 6MΩ to 60MΩ [±(2%+8)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance (F) Measurement Scope\u003c\/td\u003e\n\u003ctd\u003e60nF [±(4%+25)] | 600nF to 600μF [±(4%+5)] | 6mF to 60mF [±(10%+9)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Testing Range\u003c\/td\u003e\n\u003ctd\u003e-40℃ to 300℃ [±(1% + 20)] | 300℃ to 1000℃ [±(1% + 2)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage Frequency Range\u003c\/td\u003e\n\u003ctd\u003e10Hz to 1MHz | ±(0.1% + 3) Stated Base Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle Range Matrix\u003c\/td\u003e\n\u003ctd\u003e10% to 90% Scope | ±(2.6% + 7) Precision Boundary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Calculation Core\u003c\/td\u003e\n\u003ctd\u003eTrue RMS Processing Array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance Ratings\u003c\/td\u003e\n\u003ctd\u003eConforms to CAT III 1000V \/ CAT IV 600V | CE \/ ETL Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Mechanism Opening\u003c\/td\u003e\n\u003ctd\u003e42mm Maximum Internal Jaw Clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel Interface\u003c\/td\u003e\n\u003ctd\u003e43mm x 45mm Large LCD Screen with Dynamic Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution Count\u003c\/td\u003e\n\u003ctd\u003e6000 Count Max Display Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Trend Tracking Bar\u003c\/td\u003e\n\u003ctd\u003eIntegrated 31-Segment Active Analog Bar Graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Sampling Speed\u003c\/td\u003e\n\u003ctd\u003eDigital Screen: 3 Times \/ Second Nominal Refresh Rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Component Validation\u003c\/td\u003e\n\u003ctd\u003eContinuity Beeper Sounder | Built-in Diode Testing Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Handling Functions\u003c\/td\u003e\n\u003ctd\u003eMAX \/ MIN Capture | Relative Mode | Data Hold | Zero Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance Threshold\u003c\/td\u003e\n\u003ctd\u003e≥10MΩ High Resistance Isolation Protection (ACV\/DCV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Current Scaling\u003c\/td\u003e\n\u003ctd\u003eFlexible Current Probe Support (Optional Access up to 3000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomated Power Mitigation\u003c\/td\u003e\n\u003ctd\u003eAuto Power Off (APO) \u0026lt;50μA Sleep Current | Wake-up\/Sleep Modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5V AAA Standard Battery Cells (R03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Material Coloring\u003c\/td\u003e\n\u003ctd\u003eIndustrial Distinct Red and Grey Accent Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Net Weight\u003c\/td\u003e\n\u003ctd\u003e420g Solid Net Tool Body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Machine Dimensions\u003c\/td\u003e\n\u003ctd\u003e272mm x 81mm x 43.5mm Total Structural Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and\/or any other parameters of the item\/s and\/or product\/s and\/or system\/s supplied by the Company, may vary materially from those outlined by the Company.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAll brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND\/OR UTILISING A GIVEN PRODUCT.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eADDITIONAL RESOURCES\u003c\/h5\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT BROCHURE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eGeneral information about the Uni-T UT208B True RMS Digital Clamp Meter is mapped out in the brochure below.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":50272102514925,"sku":"UNI-UT208B","price":198.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/9529\/3345\/files\/UT208B-01.jpg?v=1783921907","url":"https:\/\/pwnps.com\/products\/uni-t-ut208b-true-rms-digital-clamp-meter","provider":"Parkway Process Solutions","version":"1.0","type":"link"}