{"product_id":"uni-t-ut202-digital-clamp-meter","title":"Uni-T UT202+ Digital Clamp Meter","description":"\u003ch6\u003eKEY FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS signal processing and automatic ranging ensure accurate calculations across variable electrical fields.\u003c\/li\u003e\n\u003cli\u003eMeasures alternating current up to 400A alongside a comprehensive 600V AC\/DC voltage checking matrix.\u003c\/li\u003e\n\u003cli\u003eIntegrated contact thermocouple tracks wide thermal fields spanning from -40℃ to 1000℃.\u003c\/li\u003e\n\u003cli\u003eLarge 4000-count digital LCD screen with low battery indication provides clear parameter tracking.\u003c\/li\u003e\n\u003cli\u003eNon-Contact Voltage (NCV) safety sensing core isolates hidden live fields without manual contact.\u003c\/li\u003e\n\u003cli\u003eMulti-mode diagnostic registry includes Min\/Max tracking, relative data modes, and a standard data hold function.\u003c\/li\u003e\n\u003cli\u003eTwenty-eight millimeter jaw opening accommodates thick industrial conductors easily during clamping routines.\u003c\/li\u003e\n\u003cli\u003eBuilt-in continuity warning and diode testing loops streamline circuit board validation profiles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Uni-T UT202+ Digital Clamp Meter delivers a highly effective and robust electrical verification framework for auditing commercial residential panels, checking climate system wiring layouts, and maintaining general industrial machinery. Standard consumer-grade diagnostic multimeters frequently require risky direct wire touching or manual range dial cycling that slows down active maintenance loops; by uniting automated hardware range allocation with built-in non-contact sensory modules, this device streamlines workplace diagnostics. Technicians can monitor active microclimates or trace failing components confidently by deploying targeted relative mode settings, safeguarding delicate processing networks while preventing calculation error tracking across busy facility fields.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eADDITIONAL FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-capacity resistance scope resolves up to 40 Mega Ohms to inspect grounding path status.\u003c\/li\u003e\n\u003cli\u003eCapacitance diagnostic tracking core safely checks motor start\/run elements up to 4 millifarads.\u003c\/li\u003e\n\u003cli\u003eAutomated power management saving infrastructure incorporates an auto power off sequence to preserve battery cells.\u003c\/li\u003e\n\u003cli\u003eDurable dual-tone red and grey industrial composite outer housing stands up to challenging worksite wear.\u003c\/li\u003e\n\u003cli\u003eSupplied heavy-duty fabric carrying bag keeps your measurement leads and technical sensors secure during everyday transit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eAPPLICATIONS\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003ePerfectly optimized for True RMS AC current clamping, AC\/DC voltage measurement, extended temperature monitoring, circuit capacitance diagnostics, non-contact voltage safety screening, and preventative maintenance building audits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePRODUCT PACKAGE INCLUDES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Uni-T UT202+ Digital Clamp Meter Base Instrument\u003c\/li\u003e\n\u003cli\u003e1 x Premium Electrical Test Leads Set\u003c\/li\u003e\n\u003cli\u003e1 x Point-Contact Temperature Thermocouple Sensor\u003c\/li\u003e\n\u003cli\u003e2 x Standard Operational AAA Batteries\u003c\/li\u003e\n\u003cli\u003e1 x Soft Protective Fabric Carrying Bag\u003c\/li\u003e\n\u003cli\u003e1 x Comprehensive English Technical Instruction Manual\u003c\/li\u003e\n\u003cli\u003e1 x 12-Month Official Factory Warranty Certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eUni-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eUT202+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Diagnostic Focus\u003c\/td\u003e\n\u003ctd\u003eAC Current, AC\/DC Voltage, and Contact Temperature Profiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Current (AC) Scope\u003c\/td\u003e\n\u003ctd\u003e400A Maximum [Accuracy Threshold: ±(2% + 10)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Frequency Range\u003c\/td\u003e\n\u003ctd\u003e50Hz to 100Hz [Accuracy Threshold: ±(1% + 5)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Voltage (AC V) Scope\u003c\/td\u003e\n\u003ctd\u003e600V Maximum [Accuracy Threshold: ±(0.8% + 5)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd\u003e10Hz to 10kHz [Accuracy Threshold: ±(1% + 5)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Voltage (DC V) Scope\u003c\/td\u003e\n\u003ctd\u003e600V Maximum [Accuracy Threshold: ±(0.5% + 2)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Measuring Range\u003c\/td\u003e\n\u003ctd\u003eUp to 40MΩ [Accuracy Threshold: ±(0.8% + 2)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measuring Range\u003c\/td\u003e\n\u003ctd\u003eUp to 4mF [Accuracy Threshold: ±(4% + 5)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Testing Range\u003c\/td\u003e\n\u003ctd\u003e-40℃ to 1000℃ [Accuracy Threshold: ±(1.5% + 5)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Calculation Core\u003c\/td\u003e\n\u003ctd\u003eTrue RMS \/ Automated Auto Range Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance Ratings\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V Standard Industry Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Safety Tools\u003c\/td\u003e\n\u003ctd\u003eNon-Contact Voltage (NCV) Sensory Module Array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel Interface\u003c\/td\u003e\n\u003ctd\u003e37mm x 25mm High-Contrast LCD Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution Count\u003c\/td\u003e\n\u003ctd\u003e4000 Count Max Display Registry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Mechanism Opening\u003c\/td\u003e\n\u003ctd\u003e28mm Internal Jaw Clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Validation Protocols\u003c\/td\u003e\n\u003ctd\u003eContinuity Beeper Test | Diode Matrix Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Handling Functions\u003c\/td\u003e\n\u003ctd\u003eMAX\/MIN Capture | Relative Mode | Data Hold Registry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e2 x AAA (Ro3) Standard Battery Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomated Power Mitigation\u003c\/td\u003e\n\u003ctd\u003eIntegrated Auto Power Off (APO) Sequence Equipped\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Material Coloring\u003c\/td\u003e\n\u003ctd\u003eIndustrial Distinct Red and Grey Accent Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Net Weight\u003c\/td\u003e\n\u003ctd\u003e248g Net Tool Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Machine Dimensions\u003c\/td\u003e\n\u003ctd\u003e215mm x 63mm x 36mm Total Frame Geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Warranty Term\u003c\/td\u003e\n\u003ctd\u003e12-Month Official Coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and\/or any other parameters of the item\/s and\/or product\/s and\/or system\/s supplied by the Company, may vary materially from those outlined by the Company.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAll brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND\/OR UTILISING A GIVEN PRODUCT.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eADDITIONAL RESOURCES\u003c\/h5\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT BROCHURE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eGeneral information about the Uni-T UT202+ Digital Clamp Meter is outlined in below brochure.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":50272085704941,"sku":"UNI-UT202+","price":55.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/9529\/3345\/files\/UT202_-01.jpg?v=1783912105","url":"https:\/\/pwnps.com\/products\/uni-t-ut202-digital-clamp-meter","provider":"Parkway Process Solutions","version":"1.0","type":"link"}