{"product_id":"testo-770-2-true-rms-clamp-meter","title":"Testo 770-2 True-rms Clamp Meter","description":"\u003ch6\u003eKEY FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eInnovative grab mechanism featuring a fully retractable pincer arm enables easy, safe diagnostics on tightly packed cables.\u003c\/li\u003e\n\u003cli\u003eNon-contact current measurement architecture is ideally suited for wire profiles with small diameters.\u003c\/li\u003e\n\u003cli\u003eAdvanced troubleshooting capacity includes dedicated microamp (µA) current testing for high-precision workflows.\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature adapter setup accommodates Type K thermocouple inputs for contact thermal profiling.\u003c\/li\u003e\n\u003cli\u003eSpecialized motor diagnostics capture transient electrical motor starting currents and high-load surges.\u003c\/li\u003e\n\u003cli\u003eAutomated measurement parameter detection instinctively configures the tool for AC or DC modes.\u003c\/li\u003e\n\u003cli\u003eTrue RMS (TRMS) calculations ensure highly accurate data tracking across noisy or distorted waves.\u003c\/li\u003e\n\u003cli\u003eConforms to high-stakes overvoltage category guidelines certified up to CAT IV 600V and CAT III 1000V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe testo 770-2 True-rms Clamp Meter delivers a highly effective and robust electrical verification framework for auditing dense commercial distribution panels, evaluating variable-speed automated lines, and maintaining complex facility heating controls. Standard consumer-grade multimeters lack the specialized structural damping and automated configuration frameworks needed for high-density diagnostics, forcing technicians to struggle with crowded cable sets; by pairing an innovative retractable hook mechanism with a secure dual-terminal jack layout, this tool guarantees rapid diagnostic clarity. Field engineers can execute expansive multi-point safety profiling across broad facility footprints confidently, tracking both microscopic microamp variations and massive power surges without introducing manual reading errors.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eADDITIONAL FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eLarge two-line LCD interface features a clear 4,000 count resolution scale and independent display lighting.\u003c\/li\u003e\n\u003cli\u003eComprehensive testing suite supports AC\/DC current up to 400A via clamp and up to 400µA via testing leads.\u003c\/li\u003e\n\u003cli\u003eBroad diagnostic capacity handles circuit capacitance up to 100.0 µF and standard resistances up to 40.00 MΩ.\u003c\/li\u003e\n\u003cli\u003eHigh internal resistance of 11 Mega Ohms (AC\/DC) prevents unwanted circuit loading faults during live line testing.\u003c\/li\u003e\n\u003cli\u003eSmart data handling profile equips independent Min\/Max value logging alongside screen freeze data hold functions.\u003c\/li\u003e\n\u003cli\u003eBuilt-in circuit validation utilities incorporate rapid continuity sounders and automated diode testing loops.\u003c\/li\u003e\n\u003cli\u003eEfficient electronic architecture derives extensive field utility utilizing three standard AAA micro batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eAPPLICATIONS\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003ePerfectly optimized for non-contact current clamping, True RMS electrical testing, high-density wire grab diagnostics, automated AC\/DC voltage checking, electrical motor starting current tracking, flame sensor microamps validation, contact temperature profiling, and safety-compliant facility engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePRODUCT PACKAGE INCLUDES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e1 x testo 770-2 True-rms Clamp Meter Base Instrument (SKU: 0590-7702)\u003c\/li\u003e\n\u003cli\u003e1 x Temperature Adapter for Type K Thermocouples\u003c\/li\u003e\n\u003cli\u003e3 x AAA Micro Batteries (For Immediate Operational Setup)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTesto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e0590-7702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Diagnostic Focus\u003c\/td\u003e\n\u003ctd\u003eNon-Contact Current Measurement on Crowded Cables \u0026amp; Conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Mechanism Profile\u003c\/td\u003e\n\u003ctd\u003eFully Retractable Pincer Arm with Unique Cable Grab Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing Core\u003c\/td\u003e\n\u003ctd\u003eTrue RMS (Root Mean Square)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation Routine Profile\u003c\/td\u003e\n\u003ctd\u003eAutomatic Measurement Parameter Detection (Auto AC\/DC Selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced Testing Capabilities\u003c\/td\u003e\n\u003ctd\u003eMotor Starting Current Tracking | High-Precision µA Current Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Current (AC A) Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 400.0 A (Clamp) | 0.1 to 400 µA (Measuring Cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Base Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% of reading + 5 Digit) [Clamp] | ±(1.5% of reading + 5 Digit) [Cables]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Current (DC A) Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 400.0 A (Clamp) | 0.1 to 400.0 µA (Measuring Cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current Base Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% of reading + 5 Digit) [Clamp] | ±(1.5% of reading + 5) [Cables]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternating Voltage (AC V) Range\u003c\/td\u003e\n\u003ctd\u003e1.0 mV to 600.0 V Maximum | ±(1.0% of reading + 3 Digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Voltage (DC V) Range\u003c\/td\u003e\n\u003ctd\u003e1.0 mV to 600.0 V Maximum | ±(0.8% of reading + 3 Digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω) Measurement Scope\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω to 40.00 MΩ Scope | ±(1.5% of reading + 3 Digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance (F) Measurement Scope\u003c\/td\u003e\n\u003ctd\u003e10 nF to 100.0 µF Scope | ±(1.5% of reading + 5 Digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Component Validation\u003c\/td\u003e\n\u003ctd\u003eContinuity Testing Loop | Integrated Diode Test Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Sensing Format\u003c\/td\u003e\n\u003ctd\u003eTemperature Adapter Included for Type K Thermocouple Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel Interface\u003c\/td\u003e\n\u003ctd\u003e2-Line LCD (Liquid Crystal Display) with Independent Display Lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution Count\u003c\/td\u003e\n\u003ctd\u003e4,000 Count Max Display Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Handling Functions\u003c\/td\u003e\n\u003ctd\u003eMin\/Max Parameter Tracking | Screen Freeze Data Hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Input Resistance\u003c\/td\u003e\n\u003ctd\u003e11 MOhm (AC \/ DC Protection Matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Overvoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V Overvoltage Ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical Standards Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1 | EN 61010-2-032 | EN 61140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Industry Authorizations\u003c\/td\u003e\n\u003ctd\u003eCE Approved | CSA Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Terminal Interface\u003c\/td\u003e\n\u003ctd\u003e2 Measuring Jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e3 x AAA Micro Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Humidity Boundary\u003c\/td\u003e\n\u003ctd\u003e0 to 80 %RH Ambient Envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 °C Environmental Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Limits\u003c\/td\u003e\n\u003ctd\u003e-15 to +60 °C (Battery Removed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Structural Coloring\u003c\/td\u003e\n\u003ctd\u003eDistinct Industrial Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Net Weight\u003c\/td\u003e\n\u003ctd\u003e378 g Solid Net Core Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Machine Dimensions\u003c\/td\u003e\n\u003ctd\u003e249 x 96 x 43 mm Total Frame Geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and\/or any other parameters of the item\/s and\/or product\/s and\/or system\/s supplied by the Company, may vary materially from those outlined by the Company.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAll brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND\/OR UTILISING A GIVEN PRODUCT.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eADDITIONAL RESOURCES\u003c\/h5\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT BROCHURE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eGeneral information about the testo 770-2 True-rms Clamp Meter is mapped out in the brochure below.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":50274815049965,"sku":"TES-0590-7702","price":480.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/9529\/3345\/files\/TES-0590-7702-01.jpg?v=1784080962","url":"https:\/\/pwnps.com\/products\/testo-770-2-true-rms-clamp-meter","provider":"Parkway Process Solutions","version":"1.0","type":"link"}