{"product_id":"fieldpiece-sc680int-trms-ac-dc-amp-clamp-meter-with-power-function","title":"Fieldpiece SC680INT TRMS AC\/DC Amp Clamp Meter with Power function","description":"\u003ch6\u003eKEY FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures Power (kW) and integrates with the Job Link® System mobile App to determine real-world system efficiency.\u003c\/li\u003e\n\u003cli\u003eTrue RMS and an integrated Low Pass Filter (LPF) capture highly accurate voltage and frequency readings on VFD components.\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600 Amps AC \u0026amp; DC through the rugged clamp jaw infrastructure.\u003c\/li\u003e\n\u003cli\u003eIndicates 3-phase rotation sequence utilizing only two standard test leads.\u003c\/li\u003e\n\u003cli\u003eDedicated Inrush current mode locks in initial motor starting amps to isolate compressor electrical spikes.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty safety ratings certified up to CAT IV-600V \/ CAT III-1000V specifications.\u003c\/li\u003e\n\u003cli\u003eHigh-contrast 10,000 count dual display screen backed by a brilliant blue auto-off backlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Fieldpiece SC680INT TRMS AC\/DC Amp Clamp Meter with Power function delivers a highly effective and robust electrical verification framework for testing multi-stage commercial cooling arrays, profiling variable-speed blowers, and auditing demanding industrial HVACR networks. While standard entry-level multimeters require separate external phase-rotation equipment and manual calculations to decipher structural power metrics, this top-of-the-line diagnostic computer coordinates multi-parameter measurements simultaneously under a single standalone casing. Technicians can deploy the integrated rear mounting magnet to affix the meter securely to access panels, leaving hands completely free to utilize gold-plated Molex tips inside dense control plugs without dropping critical test point focus or introducing tracking alignment errors.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eADDITIONAL FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eBroad structural temperature tolerance allows reliable parameter tracking across deep freezers or scorching rooftops.\u003c\/li\u003e\n\u003cli\u003ePremium gold-plated deluxe test leads feature removable protective safety sheaths to protect sensitive continuity loops.\u003c\/li\u003e\n\u003cli\u003eDual Type K thermocouple connections permit parallel temperature tracking for immediate thermal delta evaluations.\u003c\/li\u003e\n\u003cli\u003eIntelligent automatic zeroing and an integrated low-battery \"batt\" notification maintain diagnostic confidence.\u003c\/li\u003e\n\u003cli\u003eEfficient circuitry delivers up to 100 nominal operating hours from a single standard 9-volt battery cell.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eAPPLICATIONS\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003ePerfectly optimized for commercial electrical power (kW) calculation, system efficiency testing, True RMS AC\/DC current clamping, 3-phase rotation sequencing, variable frequency drive auditing, startup motor Inrush current capturing, and high-voltage HVACR component verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePRODUCT PACKAGE INCLUDES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Fieldpiece SC680INT Bluetooth TRMS AC\/DC Amp Clamp Meter (SKU: SC680INT)\u003c\/li\u003e\n\u003cli\u003e1 x ADLS2 Deluxe Test Lead Set with Gold Plated Tips and Removable Sheath\u003c\/li\u003e\n\u003cli\u003e1 x ASA2 Short Leads with Alligator Clips Set\u003c\/li\u003e\n\u003cli\u003e2 x ATB1 Type K Thermocouple Sensors\u003c\/li\u003e\n\u003cli\u003e1 x ANC7 Premium Padded Protective Carrying Case\u003c\/li\u003e\n\u003cli\u003e2 x High-Tension Velcro Storage Straps\u003c\/li\u003e\n\u003cli\u003e1 x Standard 9V Alkaline Power Battery\u003c\/li\u003e\n\u003cli\u003e1 x Comprehensive Technical Operator's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFieldpiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eSC680INT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Diagnostic Focus\u003c\/td\u003e\n\u003ctd\u003eHVAC-R Top-of-the-Line Power Monitoring \u0026amp; AC\/DC Amp Clamping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Mobile Integration\u003c\/td\u003e\n\u003ctd\u003eJob Link® System Communication Suite (Calculates kW \u0026amp; Real-Time Efficiency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement Scope\u003c\/td\u003e\n\u003ctd\u003eUp to 600 Amps AC and 600 Amps DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Calculation Architecture\u003c\/td\u003e\n\u003ctd\u003eTrue RMS via Clamp or Test Leads | Integrated Low Pass Filter (LPF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Verification Interface\u003c\/td\u003e\n\u003ctd\u003e3-Phase Rotation Sequence Tracking via Two Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel Interface\u003c\/td\u003e\n\u003ctd\u003e10,000 Count Dual Display Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Backlight System\u003c\/td\u003e\n\u003ctd\u003eBlue Color Array with 5 Minute Duration and Auto-Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection Threshold\u003c\/td\u003e\n\u003ctd\u003e1000VDC or 750VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance Rating\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V Compliance Benchmarks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Update Frequency\u003c\/td\u003e\n\u003ctd\u003e3.3 Times Per Second Nominal Sample Rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Mounting System\u003c\/td\u003e\n\u003ctd\u003eIntegrated Heavy-Duty Positioning Magnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Infrastructure\u003c\/td\u003e\n\u003ctd\u003e1 x Standard 9-Volt Alkaline Battery Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Lifespan\u003c\/td\u003e\n\u003ctd\u003eTypical 100 Hours (With Wireless and Backlight Inactive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomated Power Mitigation\u003c\/td\u003e\n\u003ctd\u003eAuto Power Off (APO) Standard Mode after ~30 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment Limits\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 122°F) at \u0026lt;70% RH Contextual Matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Limits\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C (-4°F to 140°F) at 0 to 80% RH (Battery Removed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Functional Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 6562 feet (2000 m) Operating Ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Machine Dimensions\u003c\/td\u003e\n\u003ctd\u003e247 mm (H) x 79 mm (W) x 48 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Net Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 345 g Total Weight (Including Internal Battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Package Weight\u003c\/td\u003e\n\u003ctd\u003e1.2000 kg Bulk Package Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Spatial Metrics\u003c\/td\u003e\n\u003ctd\u003e0.400m L x 0.150m W x 0.150m H [Cubic Volume: 0.009000000 m³]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Unit of Measure\u003c\/td\u003e\n\u003ctd\u003eEach (ea)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and\/or any other parameters of the item\/s and\/or product\/s and\/or system\/s supplied by the Company, may vary materially from those outlined by the Company.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAll brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND\/OR UTILISING A GIVEN PRODUCT.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eADDITIONAL RESOURCES\u003c\/h5\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT BROCHURE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eGeneral information about the Fieldpiece SC680INT TRMS AC\/DC Amp Clamp Meter is outlined in below brochure.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/4325\/8421\/files\/353083EN-C.pdf?v=1777340118\" target=\"_blank\"\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT GUIDE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eProduct Guide of Fieldpiece SC680INT TRMS AC\/DC Amp Clamp Meter can be found below.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0529\/9529\/3345\/files\/VSE_Guide_Australia_2026_e5a34ff9-1aa9-45fa-a2b7-c02c1ef2acdf.pdf?v=1778047935\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e","brand":"Parkway Process Solutions","offers":[{"title":"Default Title","offer_id":50272083181805,"sku":"FIE-SC680INT","price":641.82,"currency_code":"AUD","in_stock":true}],"url":"https:\/\/pwnps.com\/products\/fieldpiece-sc680int-trms-ac-dc-amp-clamp-meter-with-power-function","provider":"Parkway Process Solutions","version":"1.0","type":"link"}