{"product_id":"fieldpiece-sc440-trms-dual-display-clamp-meter","title":"Fieldpiece SC440 TRMS Dual Display Clamp Meter","description":"\u003ch6\u003eKEY FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes essential electrical ranges technicians use for most day-to-day HVAC-R installation and service work.\u003c\/li\u003e\n\u003cli\u003eTrue RMS calculations ensure high-accuracy testing on noisy electrical systems and variable frequency drives.\u003c\/li\u003e\n\u003cli\u003eAdvanced InRush current capture isolates initial motor startup loads to check compressor health.\u003c\/li\u003e\n\u003cli\u003eDual display screen architecture allows parallel viewing of primary electrical variables simultaneously.\u003c\/li\u003e\n\u003cli\u003eTracks high-range resistance up to 50 Mega Ohms with a ultra-fine 0.1 resolution matrix.\u003c\/li\u003e\n\u003cli\u003eIntegrated safety array features high-voltage LED beepers, continuity warnings, and non-contact voltage (NCV) checks.\u003c\/li\u003e\n\u003cli\u003eMAX hold and data hold capabilities let you focus on the test point and read results safely after disconnecting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Fieldpiece SC440 TRMS Dual Display Clamp Meter delivers a highly effective and robust electrical verification framework for testing complex industrial cooling plants, auditing commercial air conditioning infrastructure, and diagnosing furnace controls. Standard electrical testing multimeters often lack the specialized capability to measure flame rectifier microamps alongside high-load fan current, requiring field mechanics to switch between multiple independent tools; by integrating direct microamps DC logging, 400A clamping, and dual parameter viewing templates, this rugged unit simplifies high-accuracy diagnostic sequences. Operators can execute standard-compliant electrical audits, check real-time capacitor banks, and log deep component parameters safely on active jobsites without introducing manual testing errors.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eADDITIONAL FEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in test-lead holder on the clamp body improves posture and mechanical handling at high-tension connection joints.\u003c\/li\u003e\n\u003cli\u003eType K wrap-tab thermocouple attachment delivers instantaneous, direct-contact thermal verification tracking.\u003c\/li\u003e\n\u003cli\u003eDeluxe silicone lead set incorporates premium gold-plated tips and removable protective safety sheaths.\u003c\/li\u003e\n\u003cli\u003eShort alligator lead extensions provide rapid hands-free adaptation for tight control circuit boards.\u003c\/li\u003e\n\u003cli\u003eDurable padded transport case guards the electronic core from impact throughout demanding daily field transit loops.\u003c\/li\u003e\n\u003cli\u003eLow battery notification system prevents unexpected field tool failure during critical troubleshooting cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eAPPLICATIONS\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003ePerfectly optimized for True RMS current clamping, motor InRush current tracking, flame sensor microamps DC measuring, capacitance circuit diagnostics, HVAC-R component temperature checking, and high-voltage electrical safety auditing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePRODUCT PACKAGE INCLUDES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Fieldpiece SC440 True RMS Dual Display Clamp Meter (SKU: SC440)\u003c\/li\u003e\n\u003cli\u003e1 x ADLS2 Deluxe Silicone Lead Set with Gold Plated Tips and Removable Sheath\u003c\/li\u003e\n\u003cli\u003e1 x ATB1 Wrap Tab Type K Thermocouple Sensor\u003c\/li\u003e\n\u003cli\u003e1 x ASA2 Short Alligator Lead Extensions Set\u003c\/li\u003e\n\u003cli\u003e1 x Heavy-Duty ANC12 Padded Protective Carrying Case\u003c\/li\u003e\n\u003cli\u003e1 x High-Tension Velcro Storage Strap\u003c\/li\u003e\n\u003cli\u003e1 x Industrial-Grade 9V Power Battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFieldpiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eSC440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Diagnostic Focus\u003c\/td\u003e\n\u003ctd\u003eHVAC-R Electrical Range Measurements \u0026amp; True RMS Clamp Auditing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing Core\u003c\/td\u003e\n\u003ctd\u003eTrue RMS (Root Mean Square) for Dynamic Waveform Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel Interface\u003c\/td\u003e\n\u003ctd\u003eHigh-Contrast Dual Display Screen Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Alternating Current\u003c\/td\u003e\n\u003ctd\u003e400 Amps AC Clamping Range Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Current Diagnostics\u003c\/td\u003e\n\u003ctd\u003eDedicated Microamps DC Range for Flame Sensor Verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Measuring Matrix\u003c\/td\u003e\n\u003ctd\u003eUp to 50 Mega Ohms (50 MΩ) with 0.1 Resolution Threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Validation Modes\u003c\/td\u003e\n\u003ctd\u003eCapacitance Testing | Diode Evaluation | Continuity Warning Sounder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Performance Auditing\u003c\/td\u003e\n\u003ctd\u003eInRush Current Capture | Duty Cycle Percentage (%) Tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Extraction Scope\u003c\/td\u003e\n\u003ctd\u003eMeasurable Simultaneously via Test Leads and Clamp Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Safety Diagnostics\u003c\/td\u003e\n\u003ctd\u003ePush Button Non-Contact Voltage (NCV) | High-Voltage Alert LED \u0026amp; Beeper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Handling Functions\u003c\/td\u003e\n\u003ctd\u003eMAX Hold \/ Data Hold Data Memory Registries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Positioning Support\u003c\/td\u003e\n\u003ctd\u003eIntegrated Test-Lead Storage Holder Molded into Clamp Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e1 x Standard 9V Alkaline Battery (Low Battery Indicator Equipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Storage Protection\u003c\/td\u003e\n\u003ctd\u003eANC12 Heavy-Duty Padded Fabric Tool Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Package Weight\u003c\/td\u003e\n\u003ctd\u003e0.1000 kg Net Weight Allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembled Frame Dimensions\u003c\/td\u003e\n\u003ctd\u003e30.0 cm L x 15.0 cm W x 15.0 cm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Volume Metric\u003c\/td\u003e\n\u003ctd\u003e0.006750000 m³ Spatial Cubic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Unit of Measure\u003c\/td\u003e\n\u003ctd\u003eEach (ea)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe contents of this document are provided as a guide only and are subject to change without prior notice, and without any subsequent liability to Parkway Process Solutions Pty Ltd (the “Company”) or any of its related entities. The actual shape, colour, size, performance and\/or any other parameters of the item\/s and\/or product\/s and\/or system\/s supplied by the Company, may vary materially from those outlined by the Company.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAll brand names and product names outlined in this document are either trademarks or registered trademarks and belong to the respective companies.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eALL INFORMATION OUTLINED HEREIN IS PROVIDED AS A GUIDE ONLY AND SHOULD NOT BE RELIED UPON FOR ANY PURPOSE, WITHOUT CONFIRMING SUCH DETAILS WITH THE COMPANY BEFORE MAKING A PURCHASE AND\/OR UTILISING A GIVEN PRODUCT.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eADDITIONAL RESOURCES\u003c\/h5\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003ePRODUCT BROCHURE\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eGeneral information about the Fieldpiece SC440 TRMS Dual Display Clamp Meter is outlined in below brochure.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: #50809e;\"\u003eDOWNLOAD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Fieldpiece","offers":[{"title":"Default Title","offer_id":50272077054189,"sku":"FIE-SC440","price":408.18,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/9529\/3345\/files\/SC440.jpg?v=1783911513","url":"https:\/\/pwnps.com\/products\/fieldpiece-sc440-trms-dual-display-clamp-meter","provider":"Parkway Process Solutions","version":"1.0","type":"link"}